| Style Page | Material | Temperature | Voltage | Minimum thickness |
Average thickness |
Aaximum thickness |
|
| 1571 | PVC | 80 | 30 | 2 / 0.05 | 100 / 2.54 | ||
| 1007 | PVC | 80 | 300 | 13 / 0.330 | 15 / 0.381 | Optional - 60 deg C or 80 deg C Oil. | |
| 1015 | PVC | 80 | 600 | 27 / 0.685 | 30 / 0.762 | ||
| 1061 | SR-PVC | 105 | 300 | 7 / 0.177 | 9 / 0.228 | ||
| 1430 | XL-PVC | 105 | 300 | 13 / 0.330 | 15 / 0.381 | ||
| 2651 | PVC | 105 | 300 | 7 / 0.177 | 9 / 0.228 | ||
| 2468 | PVC | 80 | 300 | 13 / 0.330 | 15 / 0.381 | DC 5V | |
| 1095 | PVC | 80 | 300 | 9.5 / 0.228 | 12 / 0.241 | ||
| 1569 | PVC | 80 | 300 | 13 / 0.33 | 15 / 0.381 | ||
| 1617 | PVC | 105 | 600 | 5 / 0.127 | 40 / 1.01 | ||
| 1672 | PVC | 105 | 300 | 5 / 0.127 | 40 / 1.01 | Options: XLPVC | |
| 3302 | XL-PE | 105 | 30 | 4 / 0.10 | 100 / 2.54 | ||
| 10368 | XL-PE | 105 | 300 | 8 / 0.203 | 9 / 0.228 | ||
| 3385 | XL-PE | 105 | 300 | 13 / 0.330 | 15 / 0.381 | ||
| 3386 | XL-PE | 105 | 600 | 27 / 0.685 | 30 / 0. 762 | ||
| 3173 | XL-PE | 125 | 600 | 27 / 0.685 | 30 / 0.762 | ||
| 3265 | XL-PE | 125 | 150 | 8 / 0.203 | 10 / 0.254 | ||
| 3266 | XL-PE | 125 | 300 | 13 / 0.330 | 15 / 0.381 | ||
| 3199 | XL-PE | 105 | 300 | 27 / 0.685 | 30 / 0.762 | ||
| 2725 | PVC | 80 | 30 | 7 / 0.177 | 9 / 0.228 | ||
| 20276 | PVC | 80 | 30 | 6 / 0.152 | |||
| 10064 | FEP | 105 | 30 | 2 / 0.050 | 100 / 2.54 | ||
| 10005 | FEP | 80 | 30 | 1 / 0.025 | |||
| 1330 | FEP | 200℃ | 600 Vac | 18 / 0.457 | 20 / 0.508 | 30 AWG - 4/0 AWG, solid or stranded. | |
| 1331 | FEP | 150℃ | 600 Vac | 18 / 0.457 | 20 / 0.508 | 30 AWG - 4/0 AWG, solid or stranded. | |
| 1332 | FEP | 200℃ | 300 Vac | 12 / 0.304 | 13 / 0.33 | 30 AWG - 10 AWG solid or stranded round. |